Missouri Bids > Bid Detail

MRI Helium Refills

Agency:
Level of Government: Federal
Category:
  • 68 - Chemicals and Chemical Products
Opps ID: NBD00159209467181488
Posted Date: Feb 22, 2024
Due Date: Feb 29, 2024
Source: https://sam.gov/opp/6505a2990d...
Follow
MRI Helium Refills
Active
Contract Opportunity
Notice ID
36C25524Q0190
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Original Published Date: Feb 22, 2024 02:10 pm CST
  • Original Date Offers Due: Feb 29, 2024 11:00 am CST
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Mar 15, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6835 - MEDICAL GASES
  • NAICS Code:
    • 325120 - Industrial Gas Manufacturing
  • Place of Performance:
    MO 65201
    USA
Description

SOW: VA-BIC 7T MRI Helium Refills Contract



Purpose:




  • This contract will assure that we maintain continuous operational status of the 7T MRI by providing the necessary cryogen fills as specified by the MRI magnet operations manual. The contract will assure that the cryogens are delivered, and the MRI magnet is filled in a safe and timely manner.



Scope of Work:




  • The vendor must provide the helium fill service to maintain the liquid helium level of a 7 Tesla MRI above the operator’s manual directed minimal 679L level (probe 1 reading of 760) throughout the 12-month contract period.

  • The vendor must provide personnel that are trained in both cryogen handling and the hazards involved with a high field strength MRI magnet.

  • The vendor must provide the liquid Helium and all personal protective equipment (PPE) for their service personnel to wear while performing the helium fills.

  • The vendor will coordinate delivery of the liquid Helium with the VA BIC MRI staff so that the cryogens are on-site and adjacent to the MRI suite at the time of re-fill.

  • The Truman VA Research Service will provide all hardware necessary to conduct the fills including a liquid helium transfer line, helium gas regulator, and all related connectors/tubing to connect high purity helium gas to the liquid helium dewar. If the items are not deemed suitable by the vendor, the vendor will inform the Truman VA BIC staff and/or provide their own hardware.



Location of Work:




  • The work will be performed at the Truman VA Research Service in Rooms F017/F019, where the 7T MRI system is located.

  • The vendor must schedule the cryogen fill with the VA BIC MRI staff at least 30 days prior to the intended fill date in order for the instrument and VA BIC staff to be available for the fill.

  • On the day of the scheduled fill, the VA BIC staff must escort the vendor at all times while the vendor is in the secure area as well as to provide a second person to call for assistance in the event of a safety issue while the fill is in progress.



Period of Performance:




  • The vendor must perform liquid Helium Refills (requesting 5 helium fills during a 12-month period using 250 liters of liquid helium per fill; each fill must reach to 100% of the magnet helium level which is indicated by Probe 1 reading of 1220) in order keep the helium level above the operator’s manual directed minimal 679L level (probe 1 reading of 760) which ensures normal operation of the Truman VA Research Service 7T MRI system.

  • No vendor contacted was willing to commit to a base + 4 contract for quotes



Deliverables Schedule:




  • The vendor must perform liquid helium fills (requesting 5 helium fills during a 12-month period using 250 Liters of liquid helium per fill; each fill must reach to 100% of the magnet helium level which is indicated by Probe 1 reading of 1220) in order keep the helium level above the operator’s manual directed minimal 679L level (probe 1 reading of 760) which ensures normal operation of the Truman VA Research Service 7T MRI system.

  • The vendor must schedule the fill with the Truman VA BIC MRI staff at least 30 days prior to the intended fill date in order for the instrument to be available for the fill.

  • The vendor must arrange for the delivery of the liquid helium to be available for the scheduled fill.

  • On the day of the scheduled fill, the VA BIC staff must escort the vendor at all times while the vendor is in the secure area as well as to provide a second person to call for assistance in the event of a safety issue while the fill is in progress.



Applicable Standards:




  • There are no published standards related to the routine performance of MRI cryogen refilling.

  • The vendor must perform liquid helium fills in order keep the helium level above the operator’s manual directed minimal 679L level (probe 1 reading of 760) which ensures normal operation of the Truman VA Research Service 7T MRI system.





Acceptance Criteria:




  • Following completion of each liquid Helium Refill, VA BIC staff will verify that the liquid Helium level has been topped off (Probe 1 reading of >/= 1220) and that the magnet has been restored to fully operational status (All fill ports and vent ports closed and secured).



Special Requirements:




  • The personnel conducting the liquid helium fill must be proficient in both cryogen handling as well as the hazards involved with a high field strength MRI.

  • The vendor must arrange for the delivery of the liquid helium to be available for the scheduled fill.

  • The vendor must schedule the fill with the VA BIC MRI staff at least 30 days prior to the intended fill date in order for the instrument and VA BIC staff to be available for the fill.

  • On the day of the scheduled fill, the VA BIC staff must escort the vendor at all times while the vendor is in the secure area as well as to provide a second person to call for assistance in the event of a safety issue while the fill is in progress.


Attachments/Links
Contact Information
Contracting Office Address
  • VA MEDICAL CENTER 4101 SOUTH 4TH STREET
  • LEAVENWORTH , KS 66048
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Feb 22, 2024 02:10 pm CSTSolicitation (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.